Features:
- This product is used for quantitative detection of glucose concentration in whole blood of fingertip capillary blood vessels in vitro.
- This blood glucose test strip is only suitable for the Baijie blood glucose analyzer, which can accurately measure the concentration of glucose in your whole blood.
- When the front end of the blood glucose test strip touches the whole blood on your fingertip (pre-pulse the fingertip to get about 1-1.5 microliters of whole blood), the whole blood will be quickly absorbed into the reaction zone of the test strip. , the test time is about 10 seconds, in the blood glucose analyzer
- The results of the test are displayed on the screen. The glucose oxidase method was used to quantitatively measure the glucose
- concentration in whole blood of fingertip capillary blood vessels. The test results are only used to monitor blood glucose levels and cannot be used as a basis for drug adjustment.
Specification:
- Test Sample: Fresh Capillary Whole Blood
- Measuring time: GLU: 5sec; CHOL: 26sec; UA: 15sec
- Measuring range: GLU: 20-600 mg/dL (1.1-33.3 mmol/L) ; CHOL:100-400 mg/dL (2.59-10.35 mmol/L) ; UA: 3-20 mg/dL (0.18-1.19 mmol/L)
- Sample Volume: GLU: 0.7μL; CHOL: 10μL; AU: 1μL
- Storage & Transportation Relative Humidity: 10-90%
- Memory: 460 Test result GLU:360; CHOL:50; AU:50
- Battery Type: One 3V (CR2032) Lithium Battery
- Battery life: Approximately 1000 Test
- Dimension: 86 x 57 17 mm
- Weight About : 48g
- Expected Service life: 5 years
Testing Methods:
- 1. Remove the blood glucose test strip from the test strip and deliver immediately. Cover the test strip.
- 2. It allows you to specify the test mode before each measurement. The unit of blood glucose analyzer is the same as the measurement unit. Available in 2 milligrams per 100 milliliters or millimoles per liter (mg / dl mmol / L). Please see User guide for setting method.
- 3. Place the blood glucose test paper smoothly as the blood glucose analyzer, and the blood glucose analyzer will start to work automatically. If there is no command in 2 minutes, the blood glucose analyzer will automatically turn off, please take the paper and re-insert it.
- 4. Make sure that the blood glucose analyzer code is the same as the paper bottle code; If different, please follow the steps of blood glucose analyzer manual
- 5. with the blood needle to get the suitable amount of blood drip in the blood collection site (please follow the instructions for using the blood needle)
- 6.When the blood glucose analyzer shows the blood input indicator, gently touch the front end of the test paper, the blood drop, and the blood immediately inhaled by the test paper, enough blood begins to count down for 10 seconds after the “beep” sound.
- 7. After 10 seconds, please read the blood glucose concentration value shown by the blood glucose analyzer and the test data will be stored in the musical memory.
- 8. Remove the blood glucose test strip. If there is no instructions within 2 minutes, the blood glucose analyzer will automatically shut down. Blood collection pen, people and can’t mix
Storage Condition & Expiration:
- Storage temperature should be between 10 ° C and 30 ° C (50 ° F ~ 80 ° F). Test paper bottles should be stored in a dry and cool place. Test paper bottles should be stored away from direct sunlight or near the heat source for 24 months.